PlantScape PKS系统压力示值(底部热风)误差测量结果的不确定度评定

2009-08-12

摘 要:本文依据QJ/SY C5·051-2000计量标准考核规范,介绍了用直流信号校准PlantScape PKS系统底部风热风压力时,影响其标准不确定度的来源,最后计算出其扩展不确定度。

Uncertainty Evaluation of Error Test Result of Pressure Indication of PlantScape PKS System

BAO Qing, LI Yong

(The measure control center of Shaoguan Smelting Plant, Shaoguan 512024,China)

Abstract: According to the verification standard of QJ/SY C5·0512000, this paper introducethe sources which affect the standard uncertainty when measuring the hot breeze in the bottom of PlantScape PKS system with the direct current signal. And it computes the extended uncertainty . 